Conversion of Coal-Fired Electric Generating to Natur
boiler output can be difficult for a boiler originally designed to burn coal. Higher tube-metal temperatures may be experienced when firing natural gas. In some cases, a unit derate of 15% or more may be necessary to reduce flue gas and tube-metal (superheater, reheater) temperatures in the
DetailsFlue Gas Temperature and Heat in the Flue Gas Flow (B
Cited by: 31 The flue gas temperature can be determine in this case by an iterative process of inputting the flue gas mass flows and an assumed flue gas temperature to see if the Total Flue Gas Btu/hr is equal to 21,194.31 Btu/hour, if not you try another assumed temperature.
DetailsBoiler Efficiency - an overview | ScienceDirect Topi
The improvement in boiler efficiency can be determined by measuring the stack flue gas temperature. The stack gas temperature should decrease when the turbulators are installed. As a rule of thumb, a 2.5% increase in the boiler efficiency is expected for each 50°C (90°F) decrease in the stack flue gas temperature. •
DetailsImprove Plant Efficiency and Reduce CO2 Emissions Wh
Also, with dried coal the temperature of flue gas at the APH exit decreased, resulting in lower volumetric flow of flue gas entering the flue gas desulfurization (FGD) system, thus allowing a
DetailsAVAILABLE AND EMERGING TECHNOLOGIES FOR REDUCI
Most coal-fired EGUs in the United States burn either bituminous or subbituminous coals. Approximately one half of the tonnage of coals delivered to U.S. electric power generation facilities was subbituminous (49.5%), and another 44% was bituminous coal. Some coal-fired EGUs burn multiple coal ranks. At many of these facilities, the coals are
DetailsA flue-gas stack, also known as a smoke stack, chimney stack or simply as a stack, is a type of chimney, a vertical pipe, channel or similar structure through which combustion product gases called flue gases are exhausted to the outside air. Flue gases are produced when coal, oil, natural gas, wood or any other fuel is combusted in an industrial furnace, a power plant's steam-generating boiler
DetailsCoal fired steam boiler temperature regulation,coal fir
In the operation of coal fired steam boiler,the temperature fluctuations can cause a range of hazards,the high temperatures will cause superheater tube wall temperature rise,the low temperature will affect the the gas consumption increase of gas users,even damage the equipment,so we need to adjust the temperature of coal fired steam boiler.In this text,two adjustment ways will be introduced:
DetailsTypical Causes of Slagging and Fouling Problems in Boile
The flue gas temperatures were over 3,000F at the superheater gas side inlet. At this temperature, the ash condition was fluid, and it only took a couple of shifts to completely slag the furnace exit.
DetailsBOILER EFFICIENCY GUIDE - Cleaver-Broo
heat transfer. The stack temperature of a 4-pass boiler will be lower than the stack temperature of a 2 or 3-pass boiler, of the same basic design, operating under similar conditions. Because of this fact, the 4-pass will have higher efficiency and lower fuel cost. This is not an opinion; it is basic heat exchanger physics. The 4-pass design
DetailsFlue gas properties table - Pipe Flow Calculatio
Table of flue gases properties in relation to temperature. This table is for flue gases. It gives values of some physical properties - density and viscosity in relation to the temperature of gases.
DetailsThe National Board of Boiler and Pressure Vessel Inspecto
The cleaned steel is then exposed to the high temperature flue-gas environment, and an oxide film reforms. The oxide forms by converting steel to scale, and a little metal is lost. Each cycle of scale formation and removal reduces the wall thickness until the boiler tube is too thin to contain the fluid pressure, and failure occurs.
Details